Supply & Installation
Chillers, towers, pumps, AHUs and panels delivered, rigged, piped and wired by our own site teams — one contractor, one warranty.

MHM supplies its own chillers, cooling towers, AHUs, pumps and panels assembled in Mirpur, plus Carrier, TICA, Genius, Newin, LEO, Siemens and KMC equipment from stock or on order. The same company then installs it: rigging, foundations, chilled- and condenser-water piping, ducting, insulation, power and control wiring.
Our site teams are MHM employees, not day labour. Welders are certified, piping is pressure-tested and flushed before the evaporator is connected, ducting is leak-tested before insulation, and every panel is torque-checked and thermographed under load.
Projects run to a written programme with weekly reports, so a dyeing line or a ward is shut for hours, not days.
Everything supply & installation covers
Equipment supply
MHM-assembled units and partner brands with factory test certificates and warranty cards.
Rigging & foundations
Crane plan, RCC pads or steel frames, anti-vibration mounts and anchor bolts per our drawings.
Piping, ducting & insulation
GI/MS/PPR pipework, GI ducting to SMACNA gauges, closed-cell insulation with vapour barrier and cladding.
Power & control wiring
Feeders, starters, VFDs, sensors and BMS cabling in segregated trays and conduits.
Pump sets & water treatment
Pumps aligned on grouted bases; softeners, dosing and filtration skids piped in.
Safety & site management
Permit-to-work, hot-work control, PPE and daily toolbox talks on every MHM site.
From first call to handover
- 1
Kick-off & programme
Approved drawings, delivery dates and a shutdown plan agreed with your plant team.
- 2
Civil & rigging
Pads cured, equipment lifted and set — typically one day per chiller or tower.
- 3
Piping, ducting & electrical
Fabricated spools and ducts installed, tested, insulated; panels and cabling completed.
- 4
Pre-commissioning
Flushing, pressure tests, insulation-resistance tests and rotation checks signed off.
Supply & Installation for every part of the utility block
The service lines our engineers design, install and look after under this offering.
Chillers & Boiler Care
MHM-built air and water cooled chillers, plus descaling and treatment chemicals for boilers.
Imported Cooling Towers
Foreign-brand cooling towers, sourced, shipped, erected and commissioned by MHM.
MHM Cooling Towers
Our own FRP cooling towers — designed, moulded and assembled by MHM in Bangladesh.
Water & Fluid Utilities
Effluent treatment plants and fire hydrant & sprinkler pump systems.
Power & Electrical Utilities
Generators, transformers, UPS and battery banks, switchgear, distribution panels and voltage stabilizers.
Common questions about supply & installation
Yes. We regularly install and pipe imported chillers and towers for EPC contractors; you get the same tests and documentation.
Night and Friday shifts, temporary bypasses and staged tie-ins are planned in the programme so production is not interrupted.
Chattogram, Gazipur, Narayanganj, Savar, Mymensingh, Sylhet and Khulna are regular; further sites are quoted with lodging included.
Other services
Design & Engineering
Cooling-load calculation, equipment selection and plant-room layout with piping and electrical drawings — before a single machine is ordered.
Testing & Commissioning
Flow balancing, approach and Δt checks, vibration and electrical tests — signed off in a commissioning report you can hand to an auditor.
Annual Maintenance Contract
Scheduled visits, water-side and air-side cleaning, chemical dosing and a written log after every visit — Basic, Standard or Comprehensive.
Repair & Overhaul
Compressor swaps, motor rewinding, coil and tube cleaning, tower fill replacement and VFD retrofits — with a 48-hour diagnosis.
Genuine Spare Parts
Infill, nozzles, sprinklers, fans, motors, seals, controllers and compressors stocked in Mirpur for MHM, Carrier, TICA, Genius and Newin equipment.
Water Treatment Programme
Scale, corrosion and biological control for cooling towers, chillers and boilers — chemicals, dosing equipment, monthly analysis and one accountable engineer.
Energy Audit & Retrofit
Measured kW/TR of your existing plant and a costed retrofit plan — VFDs, chiller sequencing, tower fan control, pump right-sizing — with payback you can verify.
Talk to the team that does the work
Tell us your plant, brand and problem — an MHM engineer replies within one working day with next steps and a price.